Gelshield 200
Primers
Epoxy Primer for Osmosis Protection

    PRODUCT DESCRIPTION
    Quick drying, easy to apply, epoxy primer for protection of GRP against osmosis.
    * Provides protection against osmosis in five coats (250 µm)
    * Useable down to 5°C
    * Fast drying allows multiple coat application in a single day

    PRODUCT INFORMATION
    Colour YPA212-Green, YPA213-Grey
    Finish Matt
    Specific Gravity 1.4
    Volume Solids 45% 
    Mix Ratio 3:1 by volume (as supplied) , Converter/Curing Agent - YPA214
    Typical Shelf Life 2 yrs
    VOC (As Supplied) 464 g/lt
    Unit Size 750 ml 2.5 Lt

    DRYING/OVERCOATING INFORMATION

    Drying

    5°C 15°C 23°C 35°C


    Touch Dry [ISO] 4hrs 2hrs 1hrs 30mins
    Immersion 24hrs 18hrs 12hrs 8hrs
    Pot Life 10hrs 5hrs 3hrs 2hrs



    Overcoating
    Substrate Temperature
    5°C 15°C 23°C 35°C
    Overcoated By Min Max Min Max Min Max Min Max


    B.F.A.  10hrs  24hrs  5hrs  9hrs  3hrs  7hrs  1hrs  5hrs
    Cruiser  10hrs  24hrs  5hrs  9hrs  3hrs  7hrs  1hrs  5hrs
    Cruiser  10hrs  24hrs  5hrs  9hrs  3hrs  7hrs  1hrs  5hrs
    Cruiser Eco/Cruiser Future  10hrs  24hrs  5hrs  9hrs  3hrs  7hrs  1hrs  5hrs
    Cruiser Premium  10hrs  24hrs  5hrs  9hrs  3hrs  7hrs  1hrs  5hrs
    Cruiser UNO  10hrs  24hrs  5hrs  9hrs  3hrs  7hrs  1hrs  5hrs
    CT Kobberstoff  10hrs  24hrs  5hrs  9hrs  3hrs  7hrs  1hrs  5hrs
    Fabi  10hrs  24hrs  5hrs  9hrs  3hrs  7hrs  1hrs  5hrs
    Fabi Eco/Waterways Future  10hrs  24hrs  5hrs  9hrs  3hrs  7hrs  1hrs  5hrs
    Fabi Skeppsmask / CT Kobber  10hrs  24hrs  5hrs  9hrs  3hrs  7hrs  1hrs  5hrs
    Gelshield 200  10hrs  6mths  5hrs  6mths  3hrs  6mths  2hrs  6mths
    Interspeed  10hrs  24hrs  5hrs  9hrs  3hrs  7hrs  1hrs  5hrs
    Interspeed Aqua  10hrs  24hrs  5hrs  9hrs  3hrs  7hrs  1hrs  5hrs
    Interspeed Kopervrij  10hrs  24hrs  5hrs  9hrs  3hrs  7hrs  1hrs  5hrs
    Interspeed Ultra  10hrs  24hrs  5hrs  9hrs  3hrs  7hrs  1hrs  5hrs
    Lago Racing II  10hrs  24hrs  5hrs  9hrs  3hrs  7hrs  1hrs  5hrs
    Micron  10hrs  24hrs  5hrs  9hrs  3hrs  7hrs  1hrs  5hrs
    Micron 55  10hrs  24hrs  5hrs  9hrs  3hrs  7hrs  1hrs  5hrs
    Micron 66  10hrs  24hrs  5hrs  9hrs  3hrs  7hrs  1hrs  5hrs
    Micron Eco/Micron Future  10hrs  24hrs  5hrs  9hrs  3hrs  7hrs  1hrs  5hrs
    Micron Extra  10hrs  24hrs  5hrs  9hrs  3hrs  7hrs  1hrs  5hrs
    Micron Kopervrij  10hrs  24hrs  5hrs  9hrs  3hrs  7hrs  1hrs  5hrs
    Micron Optima  10hrs  24hrs  5hrs  9hrs  3hrs  7hrs  1hrs  5hrs
    Micron WQ  10hrs  24hrs  5hrs  9hrs  3hrs  7hrs  1hrs  5hrs
    Navigator  10hrs  24hrs  5hrs  9hrs  3hrs  7hrs  1hrs  5hrs
    Prima  10hrs  24hrs  5hrs  9hrs  3hrs  7hrs  1hrs  5hrs
    Trilux  10hrs  24hrs  5hrs  9hrs  3hrs  7hrs  1hrs  5hrs
    Trilux (S)  10hrs  24hrs  5hrs  9hrs  3hrs  7hrs  1hrs  5hrs
    Trilux 33  10hrs  24hrs  5hrs  9hrs  3hrs  7hrs  1hrs  5hrs
    Uni-Pro  10hrs  24hrs  5hrs  9hrs  3hrs  7hrs  1hrs  5hrs
    Veridian Tie Coat  10hrs  24hrs  5hrs  9hrs  3hrs  7hrs  1hrs  5hrs
    Waterways (Eire Only)  10hrs  24hrs  5hrs  9hrs  3hrs  7hrs  1hrs  5hrs


    Note:If maximum overcoating time is exceeded, sand with 180-220 grade wet or dry paper.

    APPLICATION AND USE
    Preparation BARE GRP: Wash down with Super Cleaner, rinse with fresh water and allow to dry. Sand with 180 grade (grit) paper.
    PREVIOUSLY ANTIFOULED SURFACE: Remove using Interstrip. Wash down with Super Cleaner, rinse with fresh water and allow to dry. Sand with 180 grade (grit) paper.
    EXPOSED LAMINATE: Patch prime using Gelshield solventless epoxy.


    Method Remove any dust from the surface. Apply required number of coats, detailed in the specification sheets (minimum 250 microns DFT). For ease, alternate the grey and green colours starting and ending with grey. BILGES: Apply 2 coats only provided there is a gelcoat on the inside of the hull. If no gelcoat, use Gelshield solventless epoxy.


    Hints Mixing Stir or shake individual components thoroughly. Add Curing Agent to the Base, stir and leave for 10 minutes to allow bubbles to disperse.
    Thinner YTA061 Thinners No.7
    Other Can be used down to 5°C but for maximum performance, temperature should be above 10°C.


    Some Important Points New hulls must be post-cured for a min. period of 4 weeks before applying Gelshield 200 . Do not apply direct to the exposed laminate. Do not use below 5°C. Ambient temperature should be minimum 5°C/40°F and maximum 35°C/95°F. Product temperature should be minimum 10°C and maximum 35°C. Substrate temperature should be minimum 5°C/40°F and maximum 35°C/95°F.


    Compatibility/Substrates GRP Gelcoats & cured laminate . It should not be used over any one pack products.


    Number of Coats 5 minimum by brush (min. 250 µm DFT)


    Coverage (Theoretical) - 9.10 (m²/lt) by brush

    (Practical) - 8.10 (m²/lt) by brush


    Recommended DFT 50 microns dry by brush
    Recommended WFT 110 microns wet by brush


    Application Methods Brush, Roller

    TRANSPORTATION,STORAGE AND SAFETY INFORMATION
    Storage GENERAL INFORMATION:
    Exposure to air and extremes of temperature should be avoided. For the full shelf life of Gelshield 200 to be realised ensure that between use the container is firmly closed and the temperature is between 5°C/40°F and 35°C/95°F. Keep out of direct sunlight.
    TRANSPORTATION:
    Gelshield 200 should be kept in securely closed containers during transport and storage.

    Safety GENERAL: Read the label safety section for Health and Safety Information, also available from our Technical Help Line.
    DISPOSAL: Do not discard tins or pour paint into water courses, use the facilities provided. It is best to allow paints to harden before disposal.
    Remainders of Gelshield 200 cannot be disposed of through the municipal waste route or dumped without permit. Disposal of remainders must be arranged for in consultation with the authorities.

    IMPORTANT NOTES The information given in this sheet is not intended to be exhaustive. Any person using the product without first making further written enquiries as to the suitability of the product for the intended purpose does so at their own risk and we can accept no responsibility for the performance of the product or for any loss or damage (other than death or personal or injury resulting from negligence) arising out of such use. The information contained in this sheet is liable to modification from time to time in the light of experience and our policy of continuous product development.

    , International, the Akzo Nobel logo and other products mentioned in this publication are trademarks of, or licensed to Akzo Nobel.

    Regional Addresses
    Head Office
    International Paint Ltd
    P O Box 20980
    Oriel House
    16 Connaught Place
    London W2 2ZB
    United Kingdom
    tel: +44 (0) 171 479 6000
    fax: +44 (0) 171 479 6500
    European Region
    International Paint Ltd
    Stoneygate Lane
    Felling, Gateshead
    Tyne & Wear NE10 0JY
    United Kingdom

    tel: +44 (0) 191 469 6111
    fax: +44 (0) 191 438 3977
    Asia Region
    International Paint Singapore (Pte) Ltd
    449 Tagore Industrial Avenue
    01-03 Hong Joo Industrial
    Building
    Singapore 787820

    tel: +65 6453 1981
    fax: +65 6453 1778
    Australasia Region
    International Paint
    115 Hyde Road
    Yeronga, Brisbane
    Queensland 4104
    Australia

    tel: +61 (0) 7 3892 8866
    fax: +61 (0) 7 3892 4287
    North America Region
    International Paint LLC
    2270 Morris Avenue
    Union
    New Jersey 07083
    USA

    tel: +1 (0) 908 686 1300
    fax: +1 (0) 908 686 8545
    South America Region
    International Paint
    Rod Rap tavares, KM 18.5
    Predio Administrativo 11
    Butanta CEP 05577-300
    Sao Paulo, Brazil

    tel: +55 (0) 11 3789 2000
    fax: +55 (0) 11 3789 2200


    Ref:
    Issue Date:
    Supersedes:
    05000013
    28-Jan-2008
    12-Oct-2007