Quick drying, easy to apply, epoxy primer for protection of GRP against osmosis. * Provides protection against osmosis in five coats (250 µm) * Useable down to 5°C * Fast drying allows multiple coat application in a single day |
|
| Colour |
YPA212-Green, YPA213-Grey |
| Finish |
Matt |
| Specific Gravity |
1.4 |
| Volume Solids |
45%  |
| Mix Ratio |
3:1 by volume (as supplied) , Converter/Curing Agent - YPA214 |
| Typical Shelf Life |
2 yrs |
| VOC (As Supplied) |
464 g/lt |
| Unit Size |
750 ml 2.5 Lt |
|
|
|
Drying |
|
5°C |
15°C |
23°C |
35°C |
|
|
| Touch Dry [ISO] |
4hrs |
2hrs |
1hrs |
30mins |
| Immersion |
24hrs |
18hrs |
12hrs |
8hrs |
| Pot Life |
10hrs |
5hrs |
3hrs |
2hrs |
|
|
Overcoating |
|
Substrate Temperature |
| |
5°C |
15°C |
23°C |
35°C |
| Overcoated By |
Min |
Max |
Min |
Max |
Min |
Max |
Min |
Max |
|
|
| B.F.A. |
 10hrs |
 24hrs |
 5hrs |
 9hrs |
 3hrs |
 7hrs |
 1hrs |
 5hrs |
| Cruiser |
 10hrs |
 24hrs |
 5hrs |
 9hrs |
 3hrs |
 7hrs |
 1hrs |
 5hrs |
| Cruiser |
 10hrs |
 24hrs |
 5hrs |
 9hrs |
 3hrs |
 7hrs |
 1hrs |
 5hrs |
| Cruiser Eco/Cruiser Future |
 10hrs |
 24hrs |
 5hrs |
 9hrs |
 3hrs |
 7hrs |
 1hrs |
 5hrs |
| Cruiser Premium |
 10hrs |
 24hrs |
 5hrs |
 9hrs |
 3hrs |
 7hrs |
 1hrs |
 5hrs |
| Cruiser UNO |
 10hrs |
 24hrs |
 5hrs |
 9hrs |
 3hrs |
 7hrs |
 1hrs |
 5hrs |
| CT Kobberstoff |
 10hrs |
 24hrs |
 5hrs |
 9hrs |
 3hrs |
 7hrs |
 1hrs |
 5hrs |
| Fabi |
 10hrs |
 24hrs |
 5hrs |
 9hrs |
 3hrs |
 7hrs |
 1hrs |
 5hrs |
| Fabi Eco/Waterways Future |
 10hrs |
 24hrs |
 5hrs |
 9hrs |
 3hrs |
 7hrs |
 1hrs |
 5hrs |
| Fabi Skeppsmask / CT Kobber |
 10hrs |
 24hrs |
 5hrs |
 9hrs |
 3hrs |
 7hrs |
 1hrs |
 5hrs |
| Gelshield 200 |
 10hrs |
 6mths |
 5hrs |
 6mths |
 3hrs |
 6mths |
 2hrs |
 6mths |
| Interspeed |
 10hrs |
 24hrs |
 5hrs |
 9hrs |
 3hrs |
 7hrs |
 1hrs |
 5hrs |
| Interspeed Aqua |
 10hrs |
 24hrs |
 5hrs |
 9hrs |
 3hrs |
 7hrs |
 1hrs |
 5hrs |
| Interspeed Kopervrij |
 10hrs |
 24hrs |
 5hrs |
 9hrs |
 3hrs |
 7hrs |
 1hrs |
 5hrs |
| Interspeed Ultra |
 10hrs |
 24hrs |
 5hrs |
 9hrs |
 3hrs |
 7hrs |
 1hrs |
 5hrs |
| Lago Racing II |
 10hrs |
 24hrs |
 5hrs |
 9hrs |
 3hrs |
 7hrs |
 1hrs |
 5hrs |
| Micron |
 10hrs |
 24hrs |
 5hrs |
 9hrs |
 3hrs |
 7hrs |
 1hrs |
 5hrs |
| Micron 55 |
 10hrs |
 24hrs |
 5hrs |
 9hrs |
 3hrs |
 7hrs |
 1hrs |
 5hrs |
| Micron 66 |
 10hrs |
 24hrs |
 5hrs |
 9hrs |
 3hrs |
 7hrs |
 1hrs |
 5hrs |
| Micron Eco/Micron Future |
 10hrs |
 24hrs |
 5hrs |
 9hrs |
 3hrs |
 7hrs |
 1hrs |
 5hrs |
| Micron Extra |
 10hrs |
 24hrs |
 5hrs |
 9hrs |
 3hrs |
 7hrs |
 1hrs |
 5hrs |
| Micron Kopervrij |
 10hrs |
 24hrs |
 5hrs |
 9hrs |
 3hrs |
 7hrs |
 1hrs |
 5hrs |
| Micron Optima |
 10hrs |
 24hrs |
 5hrs |
 9hrs |
 3hrs |
 7hrs |
 1hrs |
 5hrs |
| Micron WQ |
 10hrs |
 24hrs |
 5hrs |
 9hrs |
 3hrs |
 7hrs |
 1hrs |
 5hrs |
| Navigator |
 10hrs |
 24hrs |
 5hrs |
 9hrs |
 3hrs |
 7hrs |
 1hrs |
 5hrs |
| Prima |
 10hrs |
 24hrs |
 5hrs |
 9hrs |
 3hrs |
 7hrs |
 1hrs |
 5hrs |
| Trilux |
 10hrs |
 24hrs |
 5hrs |
 9hrs |
 3hrs |
 7hrs |
 1hrs |
 5hrs |
| Trilux (S) |
 10hrs |
 24hrs |
 5hrs |
 9hrs |
 3hrs |
 7hrs |
 1hrs |
 5hrs |
| Trilux 33 |
 10hrs |
 24hrs |
 5hrs |
 9hrs |
 3hrs |
 7hrs |
 1hrs |
 5hrs |
| Uni-Pro |
 10hrs |
 24hrs |
 5hrs |
 9hrs |
 3hrs |
 7hrs |
 1hrs |
 5hrs |
| Veridian Tie Coat |
 10hrs |
 24hrs |
 5hrs |
 9hrs |
 3hrs |
 7hrs |
 1hrs |
 5hrs |
| Waterways (Eire Only) |
 10hrs |
 24hrs |
 5hrs |
 9hrs |
 3hrs |
 7hrs |
 1hrs |
 5hrs |
|
|
Note:If maximum overcoating time is exceeded, sand with 180-220 grade wet or dry paper. |
|
|
| Preparation |
BARE GRP: Wash down with Super Cleaner, rinse with fresh water and allow to dry. Sand with 180 grade (grit) paper. PREVIOUSLY ANTIFOULED SURFACE: Remove using Interstrip. Wash down with Super Cleaner, rinse with fresh water and allow to dry. Sand with 180 grade (grit) paper. EXPOSED LAMINATE: Patch prime using Gelshield solventless epoxy. |
|
|
| Method |
Remove any dust from the surface. Apply required number of coats, detailed in the specification sheets (minimum 250 microns DFT). For ease, alternate the grey and green colours starting and ending with grey. BILGES: Apply 2 coats only provided there is a gelcoat on the inside of the hull. If no gelcoat, use Gelshield solventless epoxy. |
|
|
| Hints |
Mixing Stir or shake individual components thoroughly. Add Curing Agent to the Base, stir and leave for 10 minutes to allow bubbles to disperse. Thinner YTA061 Thinners No.7 Other Can be used down to 5°C but for maximum performance, temperature should be above 10°C. |
|
|
| Some Important Points |
New hulls must be post-cured for a min. period of 4 weeks before applying Gelshield 200 . Do not apply direct to the exposed laminate. Do not use below 5°C. Ambient temperature should be minimum 5°C/40°F and maximum 35°C/95°F. Product temperature should be minimum 10°C and maximum 35°C. Substrate temperature should be minimum 5°C/40°F and maximum 35°C/95°F. |
|
|
| Compatibility/Substrates |
GRP Gelcoats & cured laminate . It should not be used over any one pack products. |
|
|
| Number of Coats |
5 minimum by brush (min. 250 µm DFT) |
|
|
| Coverage |
(Theoretical) - 9.10 (m²/lt) by brush |
|
(Practical) - 8.10 (m²/lt) by brush |
|
|
| Recommended DFT |
50 microns dry by brush
|
| Recommended WFT |
110 microns wet by brush |
|
|
| Application Methods |
Brush, Roller |
|
| Storage |
GENERAL INFORMATION: Exposure to air and extremes of temperature should be avoided. For the full shelf life of Gelshield 200 to be realised ensure that between use the container is firmly closed and the temperature is between 5°C/40°F and 35°C/95°F. Keep out of direct sunlight. TRANSPORTATION: Gelshield 200 should be kept in securely closed containers during transport and storage.
|
|
|
| Safety |
GENERAL: Read the label safety section for Health and Safety Information, also available from our Technical Help Line. DISPOSAL: Do not discard tins or pour paint into water courses, use the facilities provided. It is best to allow paints to harden before disposal. Remainders of Gelshield 200 cannot be disposed of through the municipal waste route or dumped without permit. Disposal of remainders must be arranged for in consultation with the authorities.
|
|
| IMPORTANT NOTES |
The information given in this sheet is not intended to be exhaustive. Any person using the product without first making further written enquiries as to the suitability of the product for the intended purpose does so at their own risk and we can accept no responsibility for the performance of the product or for any loss or damage (other than death or personal or injury resulting from negligence) arising out of such use. The information contained in this sheet is liable to modification from time to time in the light of experience and our policy of continuous product development. |
|
 , International , the Akzo Nobel logo and other products mentioned in this publication are trademarks of, or licensed to Akzo Nobel. |
|
Head Office International Paint Ltd P O Box 20980 Oriel House 16 Connaught Place London W2 2ZB United Kingdom tel: +44 (0) 171 479 6000 fax: +44 (0) 171 479 6500 |
European Region International Paint Ltd Stoneygate Lane Felling, Gateshead Tyne & Wear NE10 0JY United Kingdom
tel: +44 (0) 191 469 6111 fax: +44 (0) 191 438 3977 |
Asia Region International Paint Singapore (Pte) Ltd 449 Tagore Industrial Avenue 01-03 Hong Joo Industrial Building Singapore 787820
tel: +65 6453 1981 fax: +65 6453 1778 |
Australasia Region International Paint 115 Hyde Road Yeronga, Brisbane Queensland 4104 Australia
tel: +61 (0) 7 3892 8866 fax: +61 (0) 7 3892 4287 |
North America Region International Paint LLC 2270 Morris Avenue Union New Jersey 07083 USA
tel: +1 (0) 908 686 1300 fax: +1 (0) 908 686 8545 |
South America Region International Paint Rod Rap tavares, KM 18.5 Predio Administrativo 11 Butanta CEP 05577-300 Sao Paulo, Brazil
tel: +55 (0) 11 3789 2000 fax: +55 (0) 11 3789 2200 |
|